| Sign In | Join Free | My entremaqueros.com | 
 | 
Brand Name : Eltek
Model Number : Smartpack S controller
Certification : CE,UL
Place of Origin : CN
MOQ : 1 piece
Price : 399 USD/pc
Supply Ability : 1000 pieces / month
Delivery Time : 3-4 weeks
Packaging Details : cartons
Brand : Eltek
Part Number : 242100.410
Product Name : Smartpack S
Model Name : Eltek Monitoring
Application : Telecom Power Systems
Input voltgae : 10 - 75 VDC
system voltage support : 12 VDC, 24VDC, 48VDC & 60VDC
Color : Black
Connection Port : RS232 / RS 485/ Ethernet / CAN /CON1 /CON 2
Weight : 2 kg
Dimension : 109 x 44 (1U) x 156 mm (4.3 x 1.75 x 6.1”)
Package : cartons

  
 
  
 Eltek Telecom Monitoring Module Smarptakc S controller for 12Vdc, 24Vdc, 48Vdc and 60Vdc Telecom System ( 242100.410)
Designed for the Flatpack S system platform, the Smartpack S finds its way into many space restricted application. Used in the 1U high, 265mm deep power racks, Smartpack S offers comprehensive monitoring and control of a 2-3kW system occupying less than 6 liters.
TELECOM – MOBILE / WIRELESS
· RADIO BASE STATIONS/ CELL SITES
· LTE / 4G / WIMAX
· DISTRIBUTED ANTENNA SYSTEMS
· BROADBAND
TELECOM – FIXED
· FIBER OPTICS / FTTX
· MICROWAVE
· CABLE
· BROADBAND
OFFSHORE AND PROCESS INDUSTRY
· SAFETY AND AUTOMATION SYSTEMS (SAS)
RAILWAY INFRASTRUCTURE
· CONTROL & PROTECTION
· SIGNALING
PARAMETERS:
| TECHNICAL SPECIFICATION | ||
| Model | Smartpack S | |
| Part number | 242100.410 | |
| INPUT DATA | ||
| Voltage (nominal) | 10 - 75 VDC | |
| Power Consumption, max - no relays energized max - all relays energized | 3,1W (display sleep) 5,5W (display on) | |
| SYSTEM CONNECTIONS - SYSTEM MONITORS | ||
| Voltage sense, system voltage support | 12 VDC, 24VDC, 48VDC & 60VDC | |
| Current sense, shunt support | 0 - 20mV and 0 - 60mV | |
| Battery fuse monitoring | Auxiliary switch NO/NC, Pull up/down | |
| Load fuse monitoring | Auxiliary switch NO/NC, Diode Matrix Pull up/down | |
| Ground fault detection | Simple bridge circuit detection | |
| SYSTEM CONNECTIONS - LVD CONTROL | ||
| Battery disconnect | 1 (latched or non-latched supported) | |
| Load disconnect | 1 (latched or non-latched supported) | |
| INPUTS AND OUTPUTS | ||
| Digital configurations, Inputs #1-6 | Auxiliary switch: NO/NC | |
| Analog configurations, Inputs #1-4 | Analog Voltage[±0 - 10V] ±4-20mA current measurement (through external 470kΩ resistor) Temperature (for NTC probe) | |
| Analog configurations, Inputs #5-6 | Analog Voltage[0-75V] Symmetry measurement | |
| Output configurations, Outputs #1-6 (alarms) | 6x Relay–Dry/Form C Configurable Normally Open/Closed [Max capacity 75V/2A/60W] | |
| USER INTERFACE | ||
| Local | 2.2” TFT 65k Colour display QVGA resolution 4 keys | |
| Ethernet port | 10/100 BASE-T HP Auto MDI/MDI-X IP protocols: HTTP / SSL, SNMP v3, MODBUS TCP and pComm UDP (PowerSuite) | |
| Serial port | RS-232 and RS-485 on RJ11 connector Serial protocols: MODBUS RTU, Modem Call-Back/SMS reporting (PSTN or GSM), COMLI, CSCP and pComm (PowerSuite) | |
| GENERAL SPECIFICATIONS | ||
| Dimensions (WxHxD) | 72.2 x 43.0 x 220.7mm (2.8 x 1.7 x 8.7”) | |
| Temperature Range | Operating -20 to +65˚C (-40 to 149˚F) | |
| DESIGN STANDARDS | ||
| Electrical safety | UL 60950-1-3rd edition, EN 60950-1-3rd edition | |
| EMC | ETSI EN 300 386 V.1.4.1 EN 61000-6-1 / -2 / -3 / -4 FCC Part 15 Subpart 109 | |
| Marine*) | DNVGL-CG-03391) | |
| Environment | ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) & 2-3 (Class 3.2) ROHS compliant | |
| 1)Only valid for part number 242100.410M | ||
Eltek Monitoring Comparsion
| CAN Device | Start | End | Numb of Nodes | 
| Smartpack | 1 | 14 | 14 | 
| Smartpack 2 Basic | 1 | 10 | 10 | 
| Smartpack 2 Master | 11 | 14 | 4 | 
| Smartnode | 17 | 30 | 14 | 
| Battery Monitor | 33 | 46 | 14 | 
| Load Monitor | 49 | 62 | 14 | 
| Flex Monitor | 65 | 78 | 14 | 
| I/O monitors | 81 | 94 | 14 | 
| Mains Monitor | 97 | 110 | 14 | 



  




  
 
 
 Solutions
 We deliver a complete and innovative solution for Telecommunication Companies, whether they are based in China or operating globally. Our site survey is a cutting-edge process, using advanced sensors and data analytics to gain a deep understanding of the site. We then create professional and future-proof plans that are designed to adapt to changing technologies and market demands. Our technical support is a team of tech-savvy experts, providing remote and on-site assistance as needed. And our maintenance services are a holistic approach to system management, focusing on energy efficiency, security, and performance. With a team of visionary professionals and a global network of partners who share our passion for innovation, we are leading the way in the telecom industry.
  
 FAQ :
1.Can I obtain samples and their price details?
2.How does your firm deal with quality - related problems?
3.How reliable are your products in terms of quality?
4.How many months of guarantee do your products have?
5.What should I do if I get low - quality products?
  
 
|   | 
| 12VDC 24VDC 48VDC Telecom Monitoring Module Smartpack S Controller RS232 242100.410 Images | 
 CE+T Power Monitoring Inview Control Inview 5 Inview Slot Inview S (P/N.:
                                                                                        
                                                        
                        
                        
                        
                                                            CE+T Power Monitoring Inview Control Inview 5 Inview Slot Inview S (P/N.:
                                                    
                        
                     HUAWEI PMU 11A Embedded Communication Power Supply Unit
                                                                                    
                        
                        
                        
                                                            HUAWEI PMU 11A Embedded Communication Power Supply Unit
                                                    
                        
                     SMU01A SMU01B SMU01C Power Monitoring Modules for Fiber Optic Equipment
                                                                                    
                        
                        
                        
                                                            SMU01A SMU01B SMU01C Power Monitoring Modules for Fiber Optic Equipment
                                                    
                        
                     Original Communication Power Supply Monitoring Module Controller SMU01C
                                                                                    
                        
                        
                        
                                                            Original Communication Power Supply Monitoring Module Controller SMU01C
                                                    
                        
                     Huawei SMU02C Communication Monitoring Module 48V DC Embedded SMU02E System
                                                                                    
                        
                        
                        
                                                            Huawei SMU02C Communication Monitoring Module 48V DC Embedded SMU02E System
                                                    
                        
                     Monitoring Communication Module Smu11c For Etp4860 Series Switch Power System
                                                                                    
                        
                        
                        
                                                            Monitoring Communication Module Smu11c For Etp4860 Series Switch Power System
                                                    
                        
                     Eltek Smartpack2 Basic 242100.501 242100.502 242100.500 Smartpack 2 Monitoring
                                                                                        
                                                        
                        
                        
                        
                                                            Eltek Smartpack2 Basic 242100.501 242100.502 242100.500 Smartpack 2 Monitoring
                                                    
                        
                     Eltek Smartpack2 Monitoring Controller Module Smartpack2 Basic P/N 242100.501
                                                                                        
                                                        
                        
                        
                        
                                                            Eltek Smartpack2 Monitoring Controller Module Smartpack2 Basic P/N 242100.501
                                                    
                        
                     CET TSI T2S ETH 2U 24V/48V Monitoring Unit Inverters Bravo Power Controller P/N
                                                                                    
                        
                        
                        
                                                            CET TSI T2S ETH 2U 24V/48V Monitoring Unit Inverters Bravo Power Controller P/N
                                                    
                        
                     Eltek Black Outdoor Telecom Monitoring Module 242100.304
                                                                                    
                        
                        
                        
                                                            Eltek Black Outdoor Telecom Monitoring Module 242100.304